Inovance E750.0 fault code meaning
Inovance / E750.0
Series: SV670NS-INT
Excessive initial position deviation between the safety encoder master and slave
servo drive
Meaning: Excessive initial position deviation between the internal master and slave of the safety encoder.
Possible causes
- Excessive initial position deviation between the internal master and slave of the safety encoder
Source: SV670NS-INT Series Servo User Manual (SIL2 Safety Version) P940
Series: SV680F-INT, SV680F, SV680LN-PLUS, SV680LP-PLUS, SV680N-INT, SV680P-INT
Excessive initial position deviation between the safety encoder master and slave
servo drive
Meaning:
Possible causes
Source: SV680F-INT Series Servo Function Manual P639; SV680F Series Servo User Manual P785; SV680LN-PLUS Direct Drive Motor Servo User Manual P873; SV680LP-PLUS Direct Drive Motor Servo User Manual P779; SV680N-INT Series Servo Function Manual P917; SV680P-INT Series Servo Function Manual P821