Inovance E631.2 fault code meaning
Inovance / E631.2
Series: IS650N-PLUS, IS810N-INT, SV630ND, SV660ND, SV680F-INT, SV680F, SV680LN-PLUS, SV680LN, SV680LP-PLUS, SV680LP, SV680N-INT, SV680P-INT
P‐MOS open circuit
servo drive
Meaning:
Possible causes
Source: IS650N-PLUS Series Servo User Manual P556; IS810N-INT Series Standard Multidrive Servo User Manual P516; SV630ND Series Servo Function Manual P475; SV660ND Series Servo Function Manual P401; SV680F-INT Series Servo Function Manual P638; SV680F Series Servo User Manual P785; SV680LN-PLUS Direct-Drive Motor Servo User Manual P872; SV680LN Direct-Drive Motor Servo Troubleshooting Manual P77; SV680LP-PLUS Direct-Drive Motor Servo User Manual P778; SV680LP Direct-Drive Motor Servo Troubleshooting Manual P70; SV680N-INT Series Servo Function Manual P920; SV680P-INT Series Servo Function Manual P824
Series: SV670NS-INT
P-MOS open circuit.
servo drive
Meaning: Holding brake circuit fault.
Possible causes
Source: SV670NS-INT Series Servo User Manual (SIL2 Safety Version) P942