Inovance E619.0 fault code meaning
Inovance / E619.0
Series: SV670N-INT, SV670P-INT, SV680F-INT, SV680LN-PLUS, SV680LP-PLUS, SV680N-INT, SV680P-INT
Absolute accuracy compensation parameter setting error
servo drive
Meaning:
Possible causes
Source: SV670N-INT Series Servo Function Manual P639; SV670P-INT Series Servo Function Manual P721; SV680F-INT Series Servo Function Manual P638; SV680LN-PLUS Direct Drive Motor Servo User Manual P872; SV680LP-PLUS Direct Drive Motor Servo User Manual P778; SV680N-INT Series Servo Function Manual P916; SV680P-INT Series Servo Function Manual P820
Series: SV670NS-INT
Absolute accuracy compensation parameter setting error
servo drive
Meaning: Incorrect accuracy compensation parameter settings
Possible causes
- 1.The accuracy compensation interval H33.64 is set to 0. 2.Inovance communication encoder DDL: 1 The distance from the mechanical home to the calibration home exceeds the upper limit of the Inovance communication encoder (encoder units 234). 2 The calibration length range exceeds the upper limit of the Inovance communication encoder (encoder units 234). 3.Homing mode record error. H33.70The parameter value is not one of {-2,-1,1,2,4,6,17,18,24,28,33,34}.
Source: SV670NS-INT Series Servo User Manual (SIL2 Safety Edition) P939