Inovance E602.6 fault code meaning
Inovance / E602.6
Series: IS650N-PLUS, SV670LN, SV670LP, SV670N-INT, SV670P-INT, SV680F-INT, SV680F, SV680LN-PLUS, SV680LP-PLUS, SV680N-INT, SV680P-INT
Angle identification does not converge
servo drive
Meaning:
Possible causes
Source: IS650N-PLUS Series Servo User Manual P555; SV670LN Direct-drive Motor Servo User Manual P117; SV670LP Direct-drive Motor Servo User Manual P123; SV670N-INT Series Servo Function Manual P641; SV670P-INT Series Servo Function Manual P723; SV680F-INT Series Servo Function Manual P638; SV680F Series Servo User Manual P163; SV680LN-PLUS Direct-drive Motor Servo User Manual P145; SV680LP-PLUS Direct-drive Motor Servo User Manual P148; SV680N-INT Series Servo Function Manual P919; SV680P-INT Series Servo Function Manual P823
Series: SV670NS-INT
Angle identification does not converge
servo drive
Meaning: Angle identification does not converge
Possible causes
- 1. External disturbances (such as vibration from other machine components) prevented angle identification from converging. 2. Inappropriate identification parameter settings prevented angle identification from converging.
Source: SV670NS-INT Series Servo User Manual (SIL2 Safety Version) P942