Inovance E602.5 fault code meaning
Inovance / E602.5
Series: IS650N-PLUS, SV680LN, SV680LP, SV680P-INT
Angle identification failure: Z signal not found
servo drive
Meaning:
Possible causes
Source: IS650N-PLUS Series Servo User Manual P555; SV680LN Direct-drive Motor Servo Troubleshooting Manual P76; SV680LP Direct-drive Motor Servo Troubleshooting Manual P70; SV680P-INT Series Servo Function Manual P823
Series: SV670N-INT, SV670P-INT, SV680F-INT, SV680F, SV680LN-PLUS, SV680LP-PLUS, SV680N-INT
Angle identification failed; z signal not found
servo drive
Meaning:
Possible causes
Source: SV670N-INT Series Servo Function Manual P641; SV670P-INT Series Servo Function Manual P723; SV680F-INT Series Servo Function Manual P638; SV680F Series Servo User Manual P784; SV680LN-PLUS Direct Drive Motor Servo User Manual P872; SV680LP-PLUS Direct Drive Motor Servo User Manual P777; SV680N-INT Series Servo Function Manual P919
Series: SV670NS-INT
Angle identification failure: Z signal not found
servo drive
Meaning: Angle identification failure: Z signal not found
Possible causes
- 1. Encoder configuration error: the actual motor encoder has no Z signal. 2. Incorrect polarity setting for the encoder Z signal. 3. Encoder feedback data error: no Z signal.
Source: SV670NS-INT Series Servo User Manual (SIL2 Safety Version) P942