Inovance E602.4 fault code meaning
Inovance / E602.4
Series: IS650N-PLUS, SV670N-INT, SV670P-INT, SV680F-INT, SV680F, SV680LN-PLUS, SV680LN, SV680LP-PLUS, SV680LP, SV680N-INT, SV680P-INT
Angle identification failure: identification timeout
servo drive
Meaning:
Possible causes
Source: IS650N-PLUS Series Servo User Manual P555; SV670N-INT Series Servo Function Manual P641; SV670P-INT Series Servo Function Manual P723; SV680F-INT Series Servo Function Manual P638; SV680F Series Servo User Manual P784; SV680LN-PLUS Direct-Drive Motor Servo User Manual P871; SV680LN Direct-Drive Motor Servo Troubleshooting Manual P76; SV680LP-PLUS Direct-Drive Motor Servo User Manual P777; SV680LP Direct-Drive Motor Servo Troubleshooting Manual P70; SV680N-INT Series Servo Function Manual P919; SV680P-INT Series Servo Function Manual P823
Series: SV670NS-INT
Angle identification failure: identification timeout
servo drive
Meaning: Angle identification failure: identification timeout
Possible causes
- Angle identification did not complete within the allotted time, triggering a timeout alarm (angle identification did not complete within half a minute). 1. External disturbances (such as vibration from other machine components) prevented the angle identification completion conditions from being met. 2. Poor encoder feedback data characteristics, interference, or errors prevented the angle identification completion conditions from being met.
Source: SV670NS-INT Series Servo User Manual (SIL2 Safety Version) P942