Series: ES680N-VARAN, ES680N, IS620F-RT, IS620F, IS650N-PLUS, IS810F, IS810N-INT, MTD-EJ, SV630A, SV630C, SV630N, SV630ND, SV630P, SV630P_C-PS, SV660A, SV660C, SV660F, SV660N, SV660ND, SV660P, SV670A, SV670LN, SV670LP, SV670N-INT, SV670P-INT, SV680F-INT, SV680F, SV680LN-PLUS, SV680LN, SV680LP-PLUS, SV680LP, SV680N-INT, SV680N, SV680P-INT, SV680P, SVD60C, SVD60N
Main circuit undervoltage
servo drive
Meaning:
Possible causes
Source: ES680N-VARAN Series Servo User Manual P229; ES680N Series Servo User Manual P205; IS620F-RT Series Servo User Manual P283; IS620F Series Servo User Manual P192; IS650N-PLUS Series Servo User Manual P555; IS810F Series Servo User Manual P294; IS810N-INT Series Standard Multi-drive Servo User Manual P515; MTD-EJ Series Servo User Manual P237; SV630A Series Servo User Manual P528; SV630C Series Servo User Manual P535; SV630N Series Servo User Manual P531; SV630ND Series Servo Function Manual P474; SV630P Series Servo User Manual P526; SV630P_C-PS Series Servo User Manual P715; SV660A Series Servo User Manual P587; SV660C Series Servo Function Manual P473; SV660F Series Servo Function Manual P377; SV660N Series Servo Function Manual P488; SV660ND Series Servo Function Manual P401; SV660P Series Servo Function Manual P424; SV670A Series Servo User Manual P658; SV670LN Direct-drive Motor Servo User Manual P747; SV670LP Direct-drive Motor Servo User Manual P673; SV670N-INT Series Servo Function Manual P641; SV670P-INT Series Servo Function Manual P722; SV680F-INT Series Servo Function Manual P637; SV680F Series Servo User Manual P784; SV680LN-PLUS Direct-drive Motor Servo User Manual P871; SV680LN Direct-drive Motor Servo Troubleshooting Manual P76; SV680LP-PLUS Direct-drive Motor Servo User Manual P777; SV680LP Direct-drive Motor Servo Troubleshooting Manual P70; SV680N-INT Series Servo Function Manual P919; SV680N Series Servo Troubleshooting Manual P75; SV680P-INT Series Servo Function Manual P823; SV680P Series Servo Troubleshooting Manual P67; SVD60C Series Servo Function Manual P640; SVD60N Series Servo Function Manual P548
Series: SV670N-LK, SV670N-PTC
Main circuit undervoltage
servo drive
Meaning: The DC bus voltage between P⊕ and N⊖ is below the fault threshold: 220V servo drive: normal value: 310V, fault threshold: 200V (the fault threshold for model S5R5 is 180V). 380V servo drive: normal value: 540V, fault threshold: 380V.
Possible causes
- 1. The main circuit power supply is unstable or experiences power loss 2. A momentary power failure occurs
- 3. The supply voltage drops during operation
- 4. phase loss: a drive requiring a 3-phase power supply is actually operating on a single-phase power supply.
- 5. servo drive fault
Source: SV670N-LK Series Servo User Manual P633; SV670N-PTC Series Servo User Manual P610
Series: SV670NS-INT
Main circuit undervoltage
servo drive
Meaning: The DC bus voltage between P⊕ and N⊖ fell below the fault threshold: 200V servo drive: normal value: 280V, fault threshold: 200V (the fault threshold for model S5R5 is 180V). 400V servo drive: normal value: 560V, fault threshold: 380V.
Possible causes
- 1. The main circuit power supply is unstable or experiences power loss 2. A momentary power failure occurs
- 3. The supply voltage drops during operation
- 4. phase loss. A drive requiring a three-phase power supply is operating on a single-phase power supply.
- 5. servo drive fault
Source: SV670NS-INT Series Servo User Manual (SIL2 Safety Version) P942