Inovance E240.0 fault code meaning

Inovance / E240.0

Series: SV670A, SV670N-INT, SV670P-INT, SV680F-INT, SV680F, SV680LN-PLUS, SV680LP-PLUS, SV680N-INT, SV680P-INT

Excessive deviation between observed and feedback electrical angles

servo drive

Meaning:

Possible causes

Source: SV670A Series Servo User Manual P658; SV670N-INT Series Servo Function Manual P640; SV670P-INT Series Servo Function Manual P722; SV680F-INT Series Servo Function Manual P637; SV680F Series Servo User Manual P784; SV680LN-PLUS Direct-Drive Motor Servo User Manual P871; SV680LP-PLUS Direct-Drive Motor Servo User Manual P777; SV680N-INT Series Servo Function Manual P919; SV680P-INT Series Servo Function Manual P823

Series: SV670N-PTC, SV670NS-INT

Excessive deviation between observed and feedback electrical angles

servo drive

Meaning: The deviation between the observed electrical angle and the electrical angle fed back by the encoder exceeds the threshold.

Possible causes

Source: SV670N-PTC Series Servo User Manual P609; SV670NS-INT Series Servo User Manual (SIL2 Safety Version) P941