Inovance E234.0 fault code meaning
Inovance / E234.0
Series: ES680N
Runaway protection
servo drive
Meaning:
Possible causes
Source: ES680N Series Servo User Manual P205
Series: ES680N-VARAN, IS620F-RT, IS620F, IS650N-PLUS, IS810F, MTD-EJ, SV630A, SV630C, SV630N, SV630ND, SV630P, SV660A, SV660C, SV660F, SV660N, SV660ND, SV660P, SV680LN, SV680LP, SVD60C, SVD60N
Runaway
servo drive
Meaning:
Possible causes
Source: ES680N-VARAN Series Servo User Manual P228; IS620F-RT Series Servo User Manual P283; IS620F Series Servo User Manual P192; IS650N-PLUS Series Servo User Manual P554; IS810F Series Servo User Manual P294; MTD-EJ Series Servo User Manual P237; SV630A Series Servo User Manual P527; SV630C Series Servo User Manual P535; SV630N Series Servo User Manual P531; SV630ND Series Servo Function Manual P474; SV630P Series Servo User Manual P525; SV660A Series Servo User Manual P587; SV660C Series Servo Function Manual P473; SV660F Series Servo Function Manual P377; SV660N Series Servo Function Manual P487; SV660ND Series Servo Function Manual P400; SV660P Series Servo Function Manual P424; SV680LN Direct Drive Motor Servo Troubleshooting Manual P76; SV680LP Direct Drive Motor Servo Troubleshooting Manual P70; SVD60C Series Servo Function Manual P639; SVD60N Series Servo Function Manual P548
Series: IS810N-INT, SV670A, SV670LN, SV670LP, SV670N-INT, SV670P-INT, SV680F-INT, SV680LN-PLUS, SV680LP-PLUS, SV680N-INT, SV680P-INT
Runaway (protection scheme 1)
servo drive
Meaning:
Possible causes
Source: IS810N-INT Series Standard Multidrive Servo User Manual P515; SV670A Series Servo User Manual P657; SV670LN Direct Drive Motor Servo User Manual P745; SV670LP Direct Drive Motor Servo User Manual P671; SV670N-INT Series Servo Function Manual P639; SV670P-INT Series Servo Function Manual P721; SV680F-INT Series Servo Function Manual P637; SV680LN-PLUS Direct Drive Motor Servo User Manual P871; SV680LP-PLUS Direct Drive Motor Servo User Manual P777; SV680N-INT Series Servo Function Manual P916; SV680P-INT Series Servo Function Manual P820
Series: SV670N-LK
Runaway
servo drive
Meaning: In torque control mode, the torque command direction is opposite to the speed feedback direction; in position or speed control mode, the speed feedback direction is opposite to the speed command direction.
Possible causes
- 1.UVW incorrect phase sequence wiring
- 2. at power-on, interference signals cause an error in motor rotor initial phase detection
- 3. incorrect encoder model or wiring
- 4. incorrect, aged, or corroded encoder wiring, or a loose encoder connector
- 5. excessive gravitational load in vertical axis applications
- 6. inappropriate parameter settings cause excessive servo vibration
Source: SV670N-LK Series Servo User Manual P632
Series: SV670N-PTC
Runaway (protection scheme 1)
servo drive
Meaning: The speed feedback direction is detected to be opposite to the torque command direction, and speed feedback meets the runaway speed threshold (H0A.57); in speed or position mode, the torque command meets the minimum of the runaway current threshold (H0A.55) and the torque limit, or in torque mode, it is not 0. The fault duration meets the runaway protection detection time (H0A.59).
Possible causes
- 1.UVW incorrect phase sequence wiring
- 2. at power-on, interference signals cause an error in motor rotor initial phase detection
- 3. incorrect encoder model or wiring
- 4. incorrect, aged, or corroded encoder wiring, or a loose encoder connector
- 5. excessive gravitational load in vertical axis applications
- 6. inappropriate parameter settings cause excessive servo vibration
Source: SV670N-PTC Series Servo User Manual P609
Series: SV670NS-INT
Runaway (protection scheme 1)
servo drive
Meaning: The speed feedback direction is detected to be opposite to the torque command direction, and the speed feedback meets the runaway speed threshold (H0A.57). In speed or position mode, the torque command meets the minimum of the runaway current threshold (H0A.55) and the torque limit; in torque mode, it is not 0. The fault duration meets the runaway protection detection time (H0A.59).
Possible causes
- 1.UVW incorrect phase sequence wiring
- 2. at power-on, interference signals cause an error in motor rotor initial phase detection
- 3. incorrect encoder model or wiring
- 4. incorrect, aged, or corroded encoder wiring, or a loose encoder connector
- 5. excessive gravitational load in vertical axis applications
- 6. inappropriate parameter settings cause excessive servo vibration
Source: SV670NS-INT Series Servo User Manual (SIL2 Safety Edition) P939
Series: SV680F
Runaway (protection scheme 1)
servo drive
Meaning:
Possible causes
Source: SV680F Series Servo User Manual P784