Inovance E203.3 fault code meaning
Inovance / E203.3
Series: SV670A, SV670LN, SV670LP, SV670N-INT, SV670P-INT, SV680F-INT, SV680F, SV680LN-PLUS, SV680LP-PLUS, SV680N-INT, SV680P-INT
Motor power cable phase W overcurrent
servo drive
Meaning:
Possible causes
Source: SV670A Series Servo User Manual P657; SV670LN Direct Drive Motor Servo User Manual P746; SV670LP Direct Drive Motor Servo User Manual P672; SV670N-INT Series Servo Function Manual P640; SV670P-INT Series Servo Function Manual P722; SV680F-INT Series Servo Function Manual P637; SV680F Series Servo User Manual P783; SV680LN-PLUS Direct Drive Motor Servo User Manual P870; SV680LP-PLUS Direct Drive Motor Servo User Manual P776; SV680N-INT Series Servo Function Manual P919; SV680P-INT Series Servo Function Manual P823
Series: SV670N-PTC, SV670NS-INT
Motor power cable phase W overcurrent
servo drive
Meaning: Phase W current measurement detects excessive current above the detection threshold.
Possible causes
- 1.Poor contact in the motor cable.
- 2.Motor cable ground fault.
- 3.Short circuit in the motor UVWcable.
- 4.Motor burned out.
Source: SV670N-PTC Series Servo User Manual P609; SV670NS-INT Series Servo User Manual (SIL2 Safety Version) P941