Inovance E174.3 fault code meaning

Inovance / E174.3

Series: CP200, MD520HS-INT, MD520HS

AI1 input error protection

AC drive

Meaning:

Possible causes

Source: CP200 Series Integrated Air Compressor Unit User Manual P71; MD520HS-INT Series High-Speed AC Drive User Manual P130; MD520HS Series High-Speed AC Drive User Manual P132

Series: MD520

AI1 input error protection

AC drive

Meaning: This fault is reported when the voltage input at port AI1 is outside the range from the lower limit (F8-45) to the upper limit (F8-46). Note: This fault is disabled by default.

Possible causes

Source: MD520 Commissioning Manual - Chinese, p. 112