Inovance E154.1 fault code meaning

Inovance / E154.1

Series: MD600, MD605

HDI open

AC drive

Meaning:

Possible causes

Source: MD600 Series Compact AC Drive User Manual P503; MD605 Series Compact AC Drive User Manual P505

Series: SV670NS-INT

Incorrect safety function trigger mode selection

servo drive

Meaning: For a model other than EtherCAT, the safety function trigger method is set to FSoE triggering.

Possible causes

Source: SV670NS-INT Series Servo User Manual (SIL2 Safety Edition) P939

Series: SV680F-INT, SV680F, SV680LN-PLUS, SV680LP-PLUS, SV680N-INT, SV680P-INT

Incorrect safety function trigger mode selection

servo drive

Meaning:

Possible causes

Source: SV680F-INT Series Servo Function Manual P636; SV680F Series Servo User Manual P783; SV680LN-PLUS Direct Drive Motor Servo User Manual P870; SV680LP-PLUS Direct Drive Motor Servo User Manual P776; SV680N-INT Series Servo Function Manual P916; SV680P-INT Series Servo Function Manual P820