Inovance E101.1 fault code meaning
Inovance / E101.1
Series: ES680N
Group H00/H01 parameter error
servo drive
Meaning:
Possible causes
Source: ES680N Series Servo User Manual P204
Series: IS620F-RT, IS620F, IS650N-PLUS, IS810F, IS810N-INT, MTD-EJ, SV630A, SV630C, SV630N, SV630ND, SV630P, SV630P_C-PS, SV660A, SV660C, SV660F, SV660N, SV660ND, SV660P, SV670A, SV670N-INT, SV670P-INT, SV680F-INT, SV680F, SV680LN-PLUS, SV680LN, SV680LP-PLUS, SV680LP, SV680N-INT, SV680N, SV680P-INT, SV680P, SVD60C, SVD60N
Parameter error in group H00/H01
servo drive
Meaning:
Possible causes
Source: IS620F-RT Series Servo User Manual P282; IS620F Series Servo User Manual P191; IS650N-PLUS Series Servo User Manual P553; IS810F Series Servo User Manual P293; IS810N-INT Series Standard Multi-drive Servo User Manual P514; MTD-EJ Series Servo User Manual P236; SV630A Series Servo User Manual P527; SV630C Series Servo User Manual P535; SV630N Series Servo User Manual P530; SV630ND Series Servo Function Manual P472; SV630P Series Servo User Manual P525; SV630P_C-PS Series Servo User Manual P714; SV660A Series Servo User Manual P586; SV660C Series Servo Function Manual P473; SV660F Series Servo Function Manual P376; SV660N Series Servo Function Manual P486; SV660ND Series Servo Function Manual P399; SV660P Series Servo Function Manual P423; SV670A Series Servo User Manual P656; SV670N-INT Series Servo Function Manual P638; SV670P-INT Series Servo Function Manual P720; SV680F-INT Series Servo Function Manual P635; SV680F Series Servo User Manual P782; SV680LN-PLUS Direct-drive Motor Servo User Manual P868; SV680LN Direct-drive Motor Servo Troubleshooting Manual P75; SV680LP-PLUS Direct-drive Motor Servo User Manual P774; SV680LP Direct-drive Motor Servo Troubleshooting Manual P69; SV680N-INT Series Servo Function Manual P915; SV680N Series Servo Troubleshooting Manual P74; SV680P-INT Series Servo Function Manual P819; SV680P Series Servo Troubleshooting Manual P66; SVD60C Series Servo Function Manual P638; SVD60N Series Servo Function Manual P547
Series: STD60N-XH, STD60N
Parameter error in group H00/H01
stepper drive
Meaning: The total number of parameters has changed, usually after a software update; parameter values in group H00 or group H01 are outside the upper or lower limits, usually after a software update.
Possible causes
- During servo power-on initialization, the parameter values in groups H00 and H01 are checked. If a parameter value exceeds its corresponding upper or lower limit, the servo displays error code E101.1. The motor parameters in group H00 are read from the encoder, and the drive parameters in group H01 are mapped according to the H01-10 drive model.
Source: STD60N-XH Series Stepper User Manual P285; STD60N Series Stepper User Manual P388
Series: SV670N-LK, SV670N-PTC
Parameter error in group H00/H01
servo drive
Meaning: The total number of parameters has changed, usually after a software update; parameter values in group H00 or group H01 are outside the upper or lower limits, usually after a software update.
Possible causes
- During servo power-on initialization, the parameter values in groups H00 and H01 are checked. If a parameter value exceeds its corresponding upper limit or falls below its lower limit, the servo displays error code E101.1. The motor parameters in group H00 are read from the encoder, and the drive parameters in group H01 are mapped according to the H01.10 drive model.
Source: SV670N-LK Series Servo User Manual P631; SV670N-PTC Series Servo User Manual P608
Series: SV670NS-INT
Parameter error in group H00/H01
servo drive
Meaning: The total number of parameters has changed, usually after a software update; parameter settings in group H00 or group H01 exceed the upper or lower limits, usually after a software update.
Possible causes
- During servo power-on initialization, parameter values in groups H00 and H01 are checked. If a parameter value exceeds its corresponding upper or lower limit, the servo displays error code E101.1. Motor parameters in group H00 are read from the encoder, and drive parameters in group H01 are mapped according to the H01.10 drive model.
Source: SV670NS-INT Series Servo User Manual (SIL2 Safety Version) P938