Inovance E082.00 fault code meaning
Inovance / E082.00
Series: MD480-PLUS, MD500-PLUS
Material feed interruption fault
AC drive
Meaning: In winding or unwinding mode, this fault is reported when the roll diameter in the normal material preparation status − B0-14 (actual roll diameter) ≥ B0-14 (actual roll diameter) xB0-52 (material break detection tolerance) for longer than B0-53 (material break detection delay).
Possible causes
- Material shortage on the winding/unwinding reel in tension control
Source: MD480-PLUS Series General-Purpose AC Drive Commissioning Manual P117; MD500-PLUS Series General-Purpose AC Drive Commissioning Manual P703