Inovance E064.00 fault code meaning
Inovance / E064.00
Series: MD480-PLUS, MD500-PLUS
Water cooling system fault
AC drive
Meaning: This fault is reported when the terminal assigned function No. 90 DI becomes active.
Possible causes
- Water-cooling system control unit fault
Source: MD480-PLUS Series General-Purpose AC Drive Commissioning Manual P117; MD500-PLUS Series General-Purpose AC Drive Commissioning Manual P702