Inovance E06.00 fault code meaning
Inovance / E06.00
Series: CA200, CA300, CP700, HVD100, MD800, MD810
Overvoltage during deceleration
AC drive
Meaning:
Possible causes
- Inappropriate overvoltage suppression setting
- An external force drives the motor during deceleration
- Deceleration time too short
- No braking unit or braking resistor is installed.
Source: CA200 Series AC Drive for Light Commercial Central Air Conditioning User Manual P30; CA300 Series Dedicated AC Drive for Central Air Conditioning User Manual P47; CP700 Series Integrated Air Compressor User Manual P101; HVD100 Series General-Purpose AC Drive User Manual P130; MD800 Series Multidrive AC Drive Maintenance Manual P44; MD810 Series Multidrive AC Drive Function Manual P252
Series: ES590
Overvoltage during deceleration
servo drive
Meaning:
Possible causes
Source: ES590 Series Servo Drive User Manual P126