Inovance E057.2 fault code meaning
Inovance / E057.2
Series: DT60
0: Coast to stop
AC drive
Meaning:
Possible causes
Source: DT60 Series Distributed AC Drive Parameter Manual P927
Series: MD520
The lower bridge arm of phase U or the upper bridge arm of phase V IGBT cannot conduct.
AC drive
Meaning: U-V+IGBT open circuit detected.
Possible causes
- U-V+IGBT open circuit
Source: MD520 Commissioning Manual - Chinese p. 104
Series: MD520HS-INT, MD520HS, MD630-JC, MD630
The lower bridge arm of phase U or the upper bridge arm of phase V IGBT cannot conduct.
AC drive
Meaning:
Possible causes
Source: MD520HS-INT Series High-Speed AC Drive User Manual P122; MD520HS Series High-Speed AC Drive User Manual P124; MD630-JC Series Machine Tool Spindle Drive User Manual P165; MD630 Series General-Purpose AC Drive Function Manual P682
Series: MD600, MD605
Self-test: phase V lower bridge arm or phase W upper bridge arm IGBT cannot conduct
AC drive
Meaning:
Possible causes
Source: MD600 Series Compact AC Drive User Manual P494; MD605 Series Compact AC Drive User Manual P496