Inovance E047.3 fault code meaning
Inovance / E047.3
Series: DT60
STO circuit power supply error
AC drive
Meaning:
Possible causes
Source: DT60 Series Distributed AC Drive Parameter Manual P926
Series: MD520
STO power supply fault
AC drive
Meaning: This fault is reported when the supply voltage of the STO circuit remains outside the specified voltage range for longer than the time threshold.
Possible causes
- STO circuit undervoltage or overvoltage
Source: MD520 Commissioning Manual - Chinese p. 104
Series: MD520HS-INT, MD520HS
STO power supply fault
AC drive
Meaning:
Possible causes
Source: MD520HS-INT Series High-Speed AC Drive User Manual P121; MD520HS Series High-Speed AC Drive User Manual P123
Series: MD630-JC, MD630
STO circuit power supply error
AC drive
Meaning:
Possible causes
Source: MD630-JC Series Machine Tool Spindle Drive User Manual P165; MD630 Series General-Purpose AC Drive Function Manual P682