Inovance E04.00 fault code meaning
Inovance / E04.00
Series: CA200, CA300, CP700, HVD100, MD810
Overcurrent at constant speed
AC drive
Meaning:
Possible causes
- Ground fault or short circuit in the AC drive output circuit
- The control mode is SVC, and auto-tuning has not been performed.
- Inappropriate overcurrent stall suppression setting
- Selected AC drive capacity is too small
- Affected by external interference
Source: CA200 Series AC Drive for Light Commercial Central Air Conditioning User Manual P30; CA300 Series Dedicated AC Drive for Central Air Conditioning User Manual P46; CP700 Series Integrated Air Compressor User Manual P100; HVD100 Series General-Purpose AC Drive User Manual P130; MD810 Series Multidrive AC Drive Function Manual P251
Series: ES590
Overcurrent at constant speed
servo drive
Meaning:
Possible causes
Source: ES590 Series Servo Drive User Manual P125