Inovance E030.1 fault code meaning

Inovance / E030.1

Series: MD520

Load loss fault

AC drive

Meaning: Asynchronous motor: This fault is triggered during run when the output current is below 25% no-load current and the synchronous frequency is below 90% rated frequency. Synchronous motor: This fault is triggered when the output current is below the load loss current threshold (default: 10%) and either the current reference exceeds the rated current or the output voltage exceeds the detection threshold (detection threshold: 50% × (back EMF +0.25 times the rated voltage)).

Possible causes

Source: MD520 Commissioning Manual - Chinese, p. 98

Series: MD520HS-INT, MD520HS

Load loss fault

AC drive

Meaning:

Possible causes

Source: MD520HS-INT Series High-Speed AC Drive User Manual P117; MD520HS Series High-Speed AC Drive User Manual P119

Series: MD600, MD605

All three output phases missing

AC drive

Meaning:

Possible causes

Source: MD600 Series Compact AC Drive User Manual P485; MD605 Series Compact AC Drive User Manual P487