Inovance E023.00 fault code meaning

Inovance / E023.00

Series: MD480-PLUS, MD500-PLUS

Overcurrent during drive output ground fault detection

AC drive

Meaning: A drive output ground fault is identified when the detected current between an output phase and ground exceeds the design threshold.

Possible causes

Source: MD480-PLUS Series General-Purpose AC Drive Commissioning Manual P110; MD500-PLUS Series General-Purpose AC Drive Commissioning Manual P695