Inovance E014.2 fault code meaning
Inovance / E014.2
Series: MD520
AC drive approaching overheat
AC drive
Meaning: The overtemperature warning threshold is calculated by subtracting the overtemperature warning margin BF-14 from the overtemperature threshold. A warning is issued when the module temperature exceeds the warning threshold.
Possible causes
- Ambient temperature too high
- Blocked air duct
- Fan damaged
- Module thermistor damaged
- Module temperature exceeds the overtemperature warning threshold
Source: MD520 Commissioning Manual - Chinese p. 92
Series: MD520HS-INT, MD520HS
AC drive approaching overheat
AC drive
Meaning:
Possible causes
Source: MD520HS-INT Series High-Speed AC Drive User Manual P111; MD520HS Series High-Speed AC Drive User Manual P113