Inovance E014.1 fault code meaning
Inovance / E014.1
Series: DT60
Drive module overtemperature
AC drive
Meaning:
Possible causes
Source: DT60 Series Distributed AC Drive Parameter Manual P915
Series: MD520
AC drive overheat
AC drive
Meaning: An AC drive overheat fault is reported when the heatsink temperature exceeds the overtemperature threshold.
Possible causes
- Ambient temperature too high
- Blocked air duct
- Fan damaged
- Module thermistor damaged
Source: MD520 Commissioning Manual - Chinese p. 91
Series: MD520HS-INT, MD520HS, MD610-INT, MD610, MD630-JC
AC drive overheat
AC drive
Meaning:
Possible causes
- Ambient temperature too high
- Blocked air duct
- Fan damaged
- Module thermistor damaged
- Module damaged
Source: MD520HS-INT Series High-Speed AC Drive User Manual P111; MD520HS Series High-Speed AC Drive User Manual P113; MD610-INT Series Standard AC Drive Quick Start Guide P100; MD610 Series Standard AC Drive Quick Start Guide P100; MD630-JC Series Machine Tool Spindle Drive User Manual P159
Series: MD600, MD605
AC drive overtemperature
AC drive
Meaning:
Possible causes
Source: MD600 Series Compact AC Drive User Manual P481; MD605 Series Compact AC Drive User Manual P483
Series: MD630
Drive overheat
AC drive
Meaning:
Possible causes
Source: MD630 Series General-Purpose AC Drive Function Manual P677