Inovance E013.2 fault code meaning

Inovance / E013.2

Series: DT60

V phase loss

AC drive

Meaning:

Possible causes

Source: DT60 Series Distributed AC Drive Parameter Manual P915

Series: IS580, MVSY, MVSY1

Output phase V loss

servo drive

Meaning:

Possible causes

Source: IS580 Series Servo Drive Function Manual P67; MVSY Series Integrated Electrohydraulic Servo Unit User Manual P105; MVSY1 Series Integrated Electrohydraulic Servo Unit User Manual P98

Series: MD520

Output phase V loss

AC drive

Meaning: Detection is performed when the run frequency exceeds 0.8Hz. The average values of the three-phase output currents are checked. If the ratio of the maximum to the minimum exceeds 10 and phase V has the minimum value, phase V loss is detected.

Possible causes

Source: MD520 Commissioning Manual - Chinese p. 91

Series: MD520HS-INT, MD520HS

Output phase V loss

AC drive

Meaning:

Possible causes

Source: MD520HS-INT Series High-Speed AC Drive User Manual P110; MD520HS Series High-Speed AC Drive User Manual P112

Series: MD600, MD605, MD610-INT, MD610, MD630-JC, MD630

Phase V loss

AC drive

Meaning:

Possible causes

Source: MD600 Series Compact AC Drive User Manual P480; MD605 Series Compact AC Drive User Manual P482; MD610-INT Series Standard AC Drive Quick Start Guide P100; MD610 Series Standard AC Drive Quick Start Guide P100; MD630-JC Series Machine Tool Spindle Drive User Manual P159; MD630 Series General-Purpose AC Drive Function Manual P677