Inovance E011.00 fault code meaning
Inovance / E011.00
Series: MD480-PLUS, MD500-PLUS
Motor overload
AC drive
Meaning: Motor overload is detected when the overload time specified by the motor overload curve is reached.
Possible causes
- Motor protection parameter F9-01 set inappropriately
- Load too large or motor locked rotor
Source: MD480-PLUS Series General-Purpose AC Drive Commissioning Manual P94; MD500-PLUS Series General-Purpose AC Drive Commissioning Manual P680