Inovance E009.3 fault code meaning
Inovance / E009.3
Series: DT60, MD520HS-INT, MD520HS, MD600, MD605, MD610-INT, MD610, MD630-JC, MD630
Pre-drive timeout
AC drive
Meaning:
Possible causes
- Input wiring is not properly connected
- Input voltage too low
- Hardware error (circuit board)
Source: DT60 Series Distributed AC Drive Parameter Manual P915; MD520HS-INT Series High-Speed AC Drive User Manual P106; MD520HS Series High-Speed AC Drive User Manual P108; MD600 Series Compact AC Drive User Manual P476; MD605 Series Compact AC Drive User Manual P478; MD610-INT Series Standard AC Drive Quick Start Guide P95; MD610 Series Standard AC Drive Quick Start Guide P95; MD630-JC Series Machine Tool Spindle Drive User Manual P158; MD630 Series General-Purpose AC Drive Function Manual P677
Series: IS580
Pre-drive timeout
servo drive
Meaning:
Possible causes
Source: IS580 Series Servo Drive Function Manual P66
Series: MD520
Pre-drive timeout
AC drive
Meaning: A pre-drive timeout is detected if, after the motor is started while the AC drive is in an undervoltage state, the DC bus voltage fails to complete power-on within 5s.
Possible causes
- Precharging error; the AC drive is started while the DC bus voltage is in an undervoltage state.
Source: MD520 Commissioning Manual - Chinese, p. 86
Series: MVSY, MVSY1
Precharging error
servo drive
Meaning:
Possible causes
Source: MVSY Series Integrated Electrohydraulic Servo Unit User Manual P104; MVSY1 Series Integrated Electrohydraulic Servo Unit User Manual P97