Inovance E008.00 fault code meaning
Inovance / E008.00
Series: MD480-PLUS, MD500-PLUS
Soft-charge resistor fault
AC drive
Meaning: A frequent contactor operation fault is detected if the relay closes multiple times within a short period without power being switched off.
Possible causes
- Input voltage outside the specified range causes the contactor to repeatedly close and open
Source: MD480-PLUS Series General-Purpose AC Drive Commissioning Manual P92; MD500-PLUS Series General-Purpose AC Drive Commissioning Manual P678