Inovance E003.00 fault code meaning
Inovance / E003.00
Series: MD480-PLUS, MD500-PLUS
Overcurrent during deceleration
AC drive
Meaning: This fault is triggered when the instantaneous output current exceeds 2.5×1.414 times the rated AC drive current during deceleration.
Possible causes
- Ground fault or short circuit in the AC drive output circuit
- The control mode is FVC or SVC, and auto-tuning has not been performed
- Deceleration time setting too short for rapid deceleration.
- Inappropriate overcurrent stall suppression setting
- No braking unit or braking resistor is installed.
- Affected by external interference
Source: MD480-PLUS Series General-Purpose AC Drive Commissioning Manual P89; MD500-PLUS Series General-Purpose AC Drive Commissioning Manual P675