Inovance E002.00 fault code meaning
Inovance / E002.00
Series: MD480-PLUS, MD500-PLUS
Overcurrent during acceleration
AC drive
Meaning: This fault is triggered when the instantaneous output current exceeds 2.5×1.414 times the rated AC drive current during acceleration.
Possible causes
- Ground fault or short circuit in the AC drive output circuit
- The control mode is FVC or SVC, and auto-tuning has not been performed
- Acceleration time setting too short for rapid acceleration.
- Inappropriate overcurrent stall suppression setting
- Inappropriate manual torque boost or V/f curve
- Starting a motor that is already rotating
- Affected by external interference
Source: MD480-PLUS Series General-Purpose AC Drive Commissioning Manual P88; MD500-PLUS Series General-Purpose AC Drive Commissioning Manual P674