Inovance E.234 fault code meaning
Inovance / E.234
Series: ES650
Runaway
servo drive
Meaning:
Possible causes
- Incorrect U V W phase sequence wiring.
- Initial phase error.
- Encoder problem
- Gravity load too large in a vertical-axis application.
- Loss of speed control due to other causes.
Source: ES650 Series Servo Drive User Manual P34