Sumitomo E08 fault code meaning

Sumitomo / E08

Series: HF-320, SF-320

EEPROM error

AC drive

Meaning: When the memory built in has problems due to noise or excessive temperature rise, this protective function engages, and the output of inverter is cut off.

Possible causes

Source:

Series: HF430

EEPROM error (note2)

AC drive

Meaning: When EEPROM in the inverter is subject to radiated noise or unusual temperature rises, the inverter output is switched off.

Possible causes

Source: