NORD E002 fault code meaning

NORD / E002

Series: SK 300E

Motor overheat (PTC)

AC drive

Meaning:

Possible causes

Source:

Series: SK 700E

Motor overtemperature (PTC): only when digital input set (function 13)

AC drive

Meaning:

Possible causes

Source:

Series: SK500E

Motor over temperature (PTC)

AC drive

Meaning: Motor temperature sensor has triggered Reduce motor load Increase motor speed Use motor external fan

Possible causes

Source: NORD SK 500E/520E Manual BU 0500 GB 6.2 Table of possible error messages P112

Series: SK750E

Motor overtemperature (PTC resistor)

AC drive

Meaning: The motor temperature sensor has picked up Reduce the load on the motor Increase motor speed Use separate ventilation for the motor 2

Possible causes

Source: NORD SK 700E/750E Manual Table of the error messages P132