Emotron OC-A fault code meaning

Emotron / OC-A

Series: VSC

Over-current at acceleration

AC drive

Meaning: 1. Acceleration time too short 2. The capacity of the motor higher than the capacity of the VSD 3. Short circuit between the motor coil and the shell 4. Short circuit between motor wiring and earth 5. IGBT module is damaged

Possible causes

Source: Emotron VSC Instruction Manual 01-3992-01r2 4.1 Error display and remedying errors P72-76