Drivecon StrF fault code meaning
Drivecon / StrF
Series: VF5100HG
Sluggishness of starting
AC drive
Meaning: Sluggishness of starting Fault relay (86A): Closed. | Note: This protection activates when running mode is not started after 10 seconds from the time starting signal is supplied to VF5100HG. Also at the time of activation of this protection, "RUN" of indicating LED on inverter unit does not illuminate and relay for running contacts (terminal block 21~23) does not activate. (1) Burning of intermediate DC fuce - "FU" of inverter unit's indicating window is turned off - replace fuse or check inverter since damage of transistor can be considered. (2) Damage of resistor for current suppression when
Possible causes
Source: Drivecon VF5100HG Instruction Manual Protective functions P36
Series: VF64
Start stall
AC drive
Meaning: Operates when Inverter is inactive even 10 sec. passed after input of run/jog command
Possible causes
Source: