ABB F0001 fault code meaning

ABB / F0001

Series: ACS150

Overcurrent

drive

Meaning: Output current has exceeded trip level. Overcurrent trip limit for drive is 325% of drive nominal current.

Possible causes

Source: ACS150 User's manual (EN, official site library.e.abb.com)

Series: ACS260

Transient overcurrent at the drive output

drive

Meaning: Transient overcurrent at the drive output. Motor overload or shock load. The fault occurs immediately when the drive is enabled or a run command is issued; the fault occurs at motor start; ensure that the motor nameplate current has been entered correctly in parameter 9906. The fault occurs when the motor runs at constant speed; the fault occurs during motor acceleration or deceleration. The acceleration/deceleration time is too short, and the required power is too high. If parameter 2202 or 2203 cannot be increased, a larger drive may be required.

Possible causes

Source: ACS260 Component Drive User Manual (3AXD50000672097) Fault Tracing P64