ABB AE30 fault code meaning
ABB / AE30
Series: ACS860-REG
FB A Communication
drive
Meaning: Loss of the cyclic communication signal between the regenerative rectifier and bus adapter module A, or between PLC and bus adapter module A.
Possible causes
Source: ACS860 Regenerative Rectifier Control Program Firmware Manual P112
Series: ACS880-BRAKE
FB A Communication
drive
Meaning: Cyclic communication signal loss between the braking unit and bus adapter module A, or between PLC and bus adapter module A.
Possible causes
Source: ACS880 Braking Control Program Firmware Manual P125
Series: ACS880-DCDC
FB A communication
drive
Meaning: Cyclic communication signal loss between the DC/DC converter unit and fieldbus adapter module A, or between PLC and fieldbus adapter module A.
Possible causes
Source: ACS880 DC _ DC Drive Control Program Firmware Manual P190
Series: ACS880-DIODE
FB A communication
drive
Meaning: 150.02 FBA A Communication loss function. Cyclic communication loss between the supply unit and fieldbus adapter module A, or between PLC and fieldbus adapter module A.
Possible causes
Source: ACS880 Diode Supply Control Program P168