ABB A582 fault code meaning

ABB / A582

Series: ACH531, ACQ531, ACQ580

Auxiliary fan missing

drive

Meaning: The auxiliary cooling fan (internal fan of IP55) is jammed or disconnected.

Possible causes

Source: ACH531 Firmware Manual P127; ACQ531 Firmware Manual P109; ACQ580 Pump Control Program Firmware Manual P182

Series: ACM510-S, ACP510

Auxiliary fan missing

drive

Meaning: The auxiliary cooling fan (connected to the fan connector on the control unit) is jammed or its connection is open.

Possible causes

Source: ACM510-01S_04S Drive Firmware Manual P356; ACP510 Standard Control Program Firmware Manual P356

Series: ACM510-V, ACS580

Auxiliary fan missing

drive

Meaning: The auxiliary cooling fan (IP55 internal fan) is jammed or disconnected.

Possible causes

Source: ACM510-01V_04V Drive Firmware Manual P399; ACS580 Standard Control Program Firmware Manual P525

Series: ACS530

Auxiliary fan missing

drive

Meaning: The auxiliary cooling fan (IP55 internal fan) is jammed or disconnected.

Possible causes

Source: ACS530 Firmware Manual P261

Series: ACS860

Auxiliary fan loss

drive

Meaning: The auxiliary cooling fan (connected to the fan connector on the control unit) is jammed or disconnected.

Possible causes

Source: ACS860 Basic Control Program Firmware Manual P300

Series: ACS880

Auxiliary fan not running

drive

Meaning: The auxiliary cooling fan (connected to the fan connector on the control unit) is jammed or disconnected.

Possible causes

Source: ACS880 Primary Control Program Firmware Manual P455

Series: ACS880-M04

Auxiliary fan missing

drive

Meaning: The auxiliary cooling fan (connected to the fan connector on the control unit) is jammed or its connection is open.

Possible causes

Source: ACS880-M04 Machinery Control Program Firmware Manual P417

Series: ACS880-MARINE

Auxiliary fan loss

drive

Meaning: The auxiliary cooling fan (connected to the fan connector on the control unit) is jammed or its connection is open.

Possible causes

Source: ACS880 Light Marine P316

Series: ACS880-POS

Auxiliary fan not running

drive

Meaning: Fault function: The auxiliary cooling fan (connected to the fan connection terminal on the control unit) is jammed or disconnected.

Possible causes

Source: ACS880 Position Control Program P443

Series: ACS880-WINCH

Auxiliary fan missing

drive

Meaning: The auxiliary cooling fan (connected to the fan connection terminal on the control unit) is jammed or disconnected.

Possible causes

Source: ACS880 Winch Control Program P549