ABB A2BA fault code meaning

ABB / A2BA

Series: ACH531, ACQ531, ACQ580

IGBT overload

drive

Meaning: Too many contacts between IGBT and the enclosure thermometer.

Possible causes

Source: ACH531 Firmware Manual P125; ACQ531 Firmware Manual P107; ACQ580 Pump Control Program Firmware Manual P181

Series: ACH580, ACS530

IGBT overload

drive

Meaning: Too many contacts between IGBT and the enclosure thermometer.

Possible causes

Source: ACH580 HVAC Control Program Firmware Manual P278; ACS530 Firmware Manual P259

Series: ACM510-S, ACP510

IGBT overload

drive

Meaning: IGBT node overtemperature.

Possible causes

Source: ACM510-01S_04S Drive Firmware Manual P354; ACP510 Standard Control Program Firmware Manual P354

Series: ACM510-V, ACS580

IGBT overload

drive

Meaning: IGBT junction temperature is too high.

Possible causes

Source: ACM510-01V_04V Drive Firmware Manual P398; ACS580 Standard Control Program Firmware Manual P523

Series: ACS180, ACS380

IGBT overload

drive

Meaning: IGBT junction and case temperatures are too high.

Possible causes

Source: ACS180 Machinery Control Program Firmware Manual P314; ACS380 Machinery Control Program Firmware Manual P427

Series: ACS280

IGBT overload

drive

Meaning: IGBT contact - enclosure overtemperature.

Possible causes

Source: ACS280 Firmware Manual P331

Series: ACS860, ACS880-MARINE

IGBT overload

drive

Meaning: IGBT overtemperature. This warning protects IGBT and can be activated by a short circuit in the motor cable.

Possible causes

Source: ACS860 Primary Control Program Firmware Manual P298; ACS880 Light Marine P313

Series: ACS880-M04, ACS880

IGBT overload

drive

Meaning: IGBT node overtemperature.

Possible causes

Source: ACS880-M04 Machinery Control Program Firmware Manual P414; ACS880 Primary Control Program Firmware Manual P453

Series: ACS880-POS, ACS880-WINCH

IGBT overload

drive

Meaning: IGBT junction temperature too high.

Possible causes

Source: ACS880 Position Control Program P441; ACS880 Winch Control Program P546