- AL-001 Emergency stop
- AL-003 Forward limit
- AL-004 Reverse limit
- AL-007 Software forward limit
- AL-008 Software reverse limit
- AL-010 Absolute position lost
- AL-015 Encoder internal overtemperature
- ER.001 Servo drive overcurrent
- ER.002 IPM fault
- ER.003 Overload [instantaneous maximum load exceeded]
- ER.004 Servo drive DC bus calibration error alarm
- ER.005 Phase U current sampling channel fault
- ER.006 Phase V current sampling channel fault
- ER.007 W phase current detection fault
- ER.008 Regenerative brake overload or overcurrent
- ER.009 DC bus undervoltage
- ER.010 DC bus overvoltage
- ER.011 Motor overspeed
- ER.012 Drive heatsink overheat
- ER.013 Servo drive software overcurrent
- ER.014 EPROM read/write error
- ER.015 Parameter copy error
- ER.016 Excessive position deviation
- ER.017 Serial encoder fault
- ER.018 Encoder ABZ signal fault
- ER.019 Encoder UVW signal fault
- ER.020 Encoder fault
- ER.021 Speed measurement fault
- ER.022 Encoder initial signal disturbed
- ER.023 Electromagnetic interference 1
- ER.024 Electromagnetic interference 2
- ER.025 Electromagnetic interference 3
- ER.026 Electromagnetic interference 4
- ER.027 Motor connection fault
- ER.028 Main circuit input phase loss
- ER.029 Drive 24V fault
- ER.030 Communication error
- ER.031 Single-board fixture test QC label NG
- ER.032 Pre-aging QC label NG
- ER.033 12-hour burn-in test label NG
- ER.034 Post-aging complete unit test label NG
- ER.039 Control board error ID
- ER.040 Motor selection logic fault
- ER.041 Soft limit alarm
- Er-001 Overcurrent
- Er-003 Overload [instantaneous maximum load exceeded]
- Er-008 Regenerative brake overload or overcurrent
- Er-009 DC bus undervoltage
- Er-010 DC bus overvoltage
- Er-011 Motor overspeed
- Er.2250 DC bus current overcurrent
- Er.2320 Motor phase current overcurrent
- Er.2350 Drive overload
- Er.3130 Input phase loss
- Er.3210 Main circuit overvoltage
- Er.3220 Main circuit undervoltage
- Er.4310 Drive overheat
- Er.5210 Current detection circuit fault
- Er.6301 Storage module fault
- Er.7110 Braking resistor fault
- Er.7121 Motor locked rotor
- Er.7122 Field fault
- Er.7305 Pulse encoder fault
- Er.7306 Input pulse frequency fault
- Er.7510 Encoder communication disconnected
- Er.7511 Encoder communication interference
- Er.8700 Bus communication error
- Er.8702 Master heartbeat timeout
- Er.8703 RPDO timeout
- Er.8704 Node
- Er.8705 CAN communication error
- Er.FF00 Drive configuration error
- Er.FF01 Motor overload
- Er.FF02 Encoder internal fault
- Er.FF04 Encoder data read error
- Er.FF05 Encoder data checksum error
- Er.FF06 Encoder data version error
- Er.FF09 Configuration parameter setting error
- Er.FF0A Output phase loss
- Er.FF0B Motor setting error
- Er.FF10 Gantry position deviation too large
- Fu.001 Overcurrent during acceleration
- Fu.002 Overcurrent during deceleration
- Fu.003 Overcurrent during operation
- Fu.004 Overvoltage during acceleration
- Fu.005 Overvoltage during deceleration
- Fu.006 Overvoltage during operation
- Fu.007 Overvoltage at stop
- Fu.008 Undervoltage during operation (maskable)
- Fu.009 Drive protection tripped
- Fu.01 Inverter acceleration overcurrent during operation
- Fu.010 Output ground fault (maskable)
- Fu.011 Electromagnetic interference
- Fu.012 Inverter overload
- Fu.013 Motor overload tripped
- Fu.014 Inverter overheat (sensor 1)
- Fu.015 Inverter overheat (sensor 2)
- Fu.016 Inverter overheat (sensor 3)
- Fu.017 External device fault or panel forced stop
- Fu.018 Speed excessive deviation (DEV)
- Fu.019 Overspeed fault (OS)
- Fu.02 Inverter deceleration overcurrent during operation
- Fu.020 PG card phase A/B pulses reversed
- Fu.021 Main contactor not closed or main circuit thyristor not conducting
- Fu.022 Internal data memory error
- Fu.023 Phase R input voltage missing (maskable)
- Fu.024 Phase S input voltage missing (maskable)
- Fu.025 Phase T input voltage missing (maskable)
- Fu.026 Phase U output current missing/too low
- Fu.027 Phase V output current missing/too low
- Fu.028 Phase W output current missing/too low
- Fu.03 Inverter run or stop overcurrent
- Fu.032 Three-phase input voltage imbalance (maskable)
- Fu.035 Software overcurrent
- Fu.039 Fin input disconnected
- Fu.04 Inverter acceleration overvoltage during operation
- Fu.040 Speed detection circuit open
- Fu.041 Motor not connected during parameter identification
- Fu.042 Phase U output open or severe parameter imbalance
- Fu.043 Phase V output open or severe parameter imbalance
- Fu.044 Phase W output open or severe parameter imbalance
- Fu.045 Motor overtemperature
- Fu.046 Motor locked rotor
- Fu.047 PG feedback signal U/V/W fault
- Fu.048 Rotor magnetic pole initial position fault
- Fu.049 Z signal identification error
- Fu.05 Inverter deceleration overvoltage during operation
- Fu.051 U phase current detection error (sensor or circuit)
- Fu.052 V phase current detection error (sensor or circuit)
- Fu.054 Temperature sensor fault (maskable)
- Fu.055 Temperature sensor 2 fault (maskable)
- Fu.056 Temperature sensor 3 fault (maskable)
- Fu.06 Inverter overvoltage during operation
- Fu.067 Function extension unit 1 communication link interrupted
- Fu.068 Function extension unit 2 fault
- Fu.07 Inverter at stop overvoltage
- Fu.071 Control board communication error
- Fu.072 Accessory connection fault
- Fu.08 Inverter undervoltage during operation
- Fu.09 Phase-to-phase short circuit fault
- Fu.1 Acceleration overcurrent during operation
- Fu.10 Inverter output ground fault (reserved)
- Fu.11 Inverter interference
- Fu.12 Inverter overload
- Fu.13 Motor overload
- Fu.130 Expansion function dedicated fault code
- Fu.14 Inverter overheat
- Fu.16 External device fault
- Fu.17 Inverter output phase loss
- Fu.18 Communication interrupted
- Fu.19 Inverter main contactor closed fault
- Fu.2 Inverter overcurrent during deceleration motion
- Fu.20 Current detection fault
- Fu.201 Parameter setting conflict
- Fu.21 Temperature sensor fault
- Fu.22 Motor not connected during parameter identification
- Fu.23 Auto-tuning fault
- Fu.24 Speed excessive deviation
- Fu.25 Three-phase input phase loss
- Fu.26 Output phase loss
- Fu.27 DC fan 1 fault
- Fu.28 DC fan 2 fault
- Fu.3 Inverter run or stop overcurrent
- Fu.30 Inverter cannot normal detection motor parameter
- Fu.309 Current detection fault
- Fu.31 Phase U motor parameter error
- Fu.311 Control board fault
- Fu.32 Phase V motor parameter error
- Fu.33 Phase W motor parameter error
- Fu.34 Phase W motor parameter error
- Fu.35 Software overcurrent
- Fu.4 Inverter acceleration overvoltage during operation
- Fu.40 Internal data memory error
- Fu.5 Inverter deceleration overvoltage during operation
- Fu.6 Inverter overvoltage during operation
- Fu.7 Inverter at stop overvoltage
- Fu.8 Inverter undervoltage during operation
- Fu.800 Oil temperature overlimit fault
- Fu.801 Oil-temperature sensor fault
- Fu.803 Motor temperature sensor fault
- Fu.804 Motor temperature out of range
- Fu.805 System initialization failure
- Fu.808 Communication error
- Fu.9 Inverter drive protection tripped
- aL.008 Input undervoltage (undervoltage pre-alarm)
- aL.011 Harsh electromagnetic environment
- aL.012 Load too heavy, protection may occur
- aL.014 INV overtemperature pre-alarm
- aL.018 Speed excessive deviation (DEV)
- aL.019 Overspeed (OS)
- aL.031 Start permit signal missing
- aL.032 Three-phase input voltage imbalance warning
- aL.038 AI1 input disconnected
- aL.039 Fin input disconnected
- aL.040 Speed detection circuit open
- aL.041 No-load run motor parameter identification failed
- aL.044 Motor U phase parameter error
- aL.045 Motor overtemperature
- aL.046 Synchronous motor rotor magnetic pole position dynamic tracking out of bounds
- aL.047 Z signal loss or auto-tuning fault
- aL.049 Drive circuit error imbalance
- aL.050 Motor may not be connected correctly
- aL.054 Temperature sensor fault
- aL.056 Temperature sensor 1 fault
- aL.058 Cannot batch-restore parameters during run
- aL.059 Cannot restore power-on values during run
- aL.061 Expansion communication module link to main control board interrupted
- aL.062 Function expansion unit 1 hardware conflict
- aL.063 Function expansion unit 2 hardware conflict
- aL.064 Function expansion unit resource conflict
- aL.065 Cannot establish communication with function expansion unit 1
- aL.066 Cannot establish communication with function expansion unit 2
- aL.067 Function extension unit 1 communication link interrupted
- aL.068 Function extension unit 2 communication link interrupted
- aL.072 Panel memory operation failed
- aL.073 Panel memory write prohibited; cannot download parameters
- aL.074 Parameter upload failed (auto-restored to pre-upload values)
- aL.075 Panel parameter version differs from device; upload not possible
- aL.076 Panel has no valid parameters; cannot upload
- aL.077 Panel parameters outside INV allowed range; upload failed
- aL.099 Operator panel connection fault
- aL.100 EMI caused control program runaway
- aL.101 Setting parameter conflict
- aL.102 Set parameter has no corresponding expansion card connected
- aL.103 Motor parameter setting conflict (rated frequency/speed conflict)
- aL.105 Motor stator inductance parameter overflow (motor parameters set incorrectly)
- aL.106 Synchronous motor rated frequency, speed, pole-pairs setting conflict
- aL.130 Expansion dedicated
- aL.201 Parameter setting conflict; about to stop
- d-15 First fault record
- d-16 Second fault record
- d-17 Third fault record
- d-18 Fourth fault record
- d-20 First fault record
- d-21 Second fault record
- d-22 Third fault record
- d-23 Fourth fault record
- d-24 Output frequency at last fault
- d-25 Output current at most recent fault
- d1-00 Last fault record
- d1-01 Historical fault record 1
- d1-02 Historical fault record 2
- d1-03 Historical fault record 3
- d1-04 Historical fault record 4
- d1-05 Historical fault record 5
- d1-06 Output frequency at last fault