Fault codes
- A.EF ABN.STOP external fault
- A.OH A.STOP overheat pow.mod
- A.OH2 ABN.STOP motor protect.
- A.OHI ABN.STOP overheat int.
- A.OL ABN.STOP overload
- A.OL2 Overload 2 warning
- A.PrF ABN.STOP prot. rot. for.
- A.Prr A.Prr GB
- A.SEt ABN.STOP set
- A.SLF ABN.Software limit switch forward
- A.SLr A.SLr GB34
- A.SbuS ABN.Bus synchron
- A.buS ABN.STOP bus
- A.dOH ABN.STOP drive over heat
- A.nOH Power module overheat warning cleared
- A.nOHI Internal overheat warning cleared
- A.nOL no ABN.STOP overload
- A.nOL2 Overload 2 warning cleared
- A.ndOH Motor overtemperature warning cleared
- BdInt Interface Card not recognized
- BdPPr Enc. ppr does not match
- E.BR Braking fault
- E.CO1 Encoder 1 count overflow
- E.CO2 Encoder 2 count overflow
- E.Cdd ERROR calc. drive data
- E.DRI Inverter relay fault
- E.EEP ERROR EEPROM defective t
- E.EF ERROR external fault
- E.ENC E.EnC E
- E.EnC E.EnC E
- E.EnC1 Encoder Signal Loss
- E.EnCC Encoder Communication Error
- E.HYB Encoder signal disordered
- E.HYBc Encoder fault
- E.Hyb ERROR hybrid
- E.HybC ERROR hybrid changed
- E.INI E.InI GB30
- E.InI E.InI GB30
- E.LSF ERROR load shunt fault
- E.OC ERROR overcurrent
- E.OH ERROR overheat pow.mod.
- E.OH2 ERROR motor protection
- E.OHI ERROR overheat internal
- E.OL ERROR overload (Ixt)
- E.OL2 ERROR overload 2
- E.OP Overvoltage
- E.OS ERROR over speed
- E.PFC ERROR Power factor control
- E.PRF Forward inhibited (forward limit)
- E.PRR Reverse block
- E.PU ERROR power unit
- E.PUC Power unit replaced
- E.PUCI Illegal power unit number
- E.PUCO ERROR power unit commun.
- E.PUIN ERROR power unit invalid
- E.PrF E.PrF GB
- E.Prr ERROR prot. rot. rev.
- E.Pu ERROR power unit
- E.PuCH Power Unit Code Changed
- E.Puch ERROR power unit changed
- E.Puci ERROR pow. unit code inv.
- E.Puco Power unit communication error
- E.SET Parameter set error
- E.SEt ERROR set
- E.SLF ERROR! Software limit switch forward
- E.SLr E.SLr GB32
- E.SbuS ERROR bus synchron
- E.UP ERROR underpotential
- E.UPh ERROR Phase failure Warning Messages
- E.br E. br GB
- E.buS ERROR bus
- E.bus Communication bus error
- E.ccD Inverter calculation error
- E.co1 ERROR counter overrun 1
- E.co2 ERROR counter overrun 2
- E.dOH ERROR drive overheat
- E.dri ERROR driver relay
- E.iEd ERROR input error detect
- E.nOH Power module overheat cleared
- E.nOHI Internal overheat cleared
- E.nOL no ERROR overload
- E.nOL2 Overload 2 cleared
- E.ndOH Motor overtemperature cleared
- E.ndoH Motor overtemperature fault cleared
- EncBS Encoder busy
- EncId Unknown encoder ID
- ErEnc Internal encoder failure
- FrtEn Formatting the encoder
- No.PU Power unit not ready
- OFF No com to Enc. Card
- OHEnc Encoder over heat
- OSEnc Encoder over speed
- PoSde Position deviation too high
- bbL Base Block Time
- bdCba Cable break. abs. channels
- bdCbi Cable break. inc. channels
- bdSuP Bad internal enc. supply
- conn Serial Com. Established
- nEEnc New encoder found
- noFrt Encoder memory not formatted