BONFIGLIOLI fault codes
Fault codes
- -LV- Voltage too low during stop
- -OH- Inverter overheat at stop
- -OV- Voltage too high during stop
- ATER Auto-tuning faults
- CPF Program problem
- CTER Current Sensor detecting error
- E.S. External emergency stop
- EPR EEPROM problem
- EPr1 Parameter setting error copy unit failed
- EPr2 Parameter not match
- Err1 Key operation error
- Err2 Parameter setting error
- Err4 Illegal interrupt of CPU
- Err5 Cannot change parameters during communication
- Err6 Communication failed
- Err7 Parameter conflict
- Err8 Factory setting error
- F0100 Frequency inverter overloaded.
- F0102 Inverter overload (60 s)
- F0103 Short-time overload (1 s)
- F0200 Heatsink overtemperature
- F0201 Temperature sensor fault or ambient temperature too low
- F0300 Internal overtemperature
- F0301 Internal temperature too low
- F0400 Motor overtemperature or sensor fault
- F0401 Motor protection switch tripped
- F0402 V-belt monitoring: drive unloaded
- F0403 Motor phase loss
- F0500 Output overload
- F0503 Output short circuit or ground fault
- F0504 Overload (current limit controller)
- F0505 Motor current asymmetry
- F0506 Motor phase current too high
- F0507 Phase monitoring alarm
- F0700 DC bus voltage too high
- F0701 DC bus voltage too low
- F0702 Power supply fault (power loss)
- F0703 Input phase loss
- F0704 DC bus limit setpoint (parameter 680) too small
- F0705 Braking chopper trigger threshold (parameter 506) too low
- F0706 Motor chopper trigger threshold (parameter 507) too small
- F0801 24 V electronics supply voltage too low
- F0804 Electronics supply voltage too high
- F0A10 Cannot transfer data from operator unit KP500 to inverter
- F0B13 Communication module inserted in slot B without power-off
- F1010 Brake chopper overcurrent
- F1100 Output frequency too high
- F1101 Control reached maximum frequency
- F1201 STO function diagnostic error (STOA/STOB cut-off channel fault)
- F1204 Software self-diagnosis detected internal error
- F1205 STO 5 s monitoring fault (STOA and STOB not synchronized)
- F1300 Output ground fault
- F1301 IDC compensation limit reached (parameter 415)
- F1310 Minimum current monitoring
- F1401 Multi-function input 1 reference error
- F1407 Multi-function input 1 overcurrent
- F1430 Encoder signal fault
- F1431 One speed sensor signal missing
- F1432 Speed sensor rotation direction fault
- F1436 Encoder 1
- F1437 Encoder not enabled
- F1454 External fault
- LOC Parameter and frequency reverse already locked
- LV-C Voltage too low during operation
- OC Over-current during stop
- OC-A Over-current at acceleration
- OC-C Over-current at fixed speed
- OC-D Over-current at deceleration
- OC-S Over current at start
- OH-C Heatsink temperature too high during operation
- OL1 Motor overload
- OL2 Inverter overload
- OL3 Over torque
- OV-C Voltage too high during operation/deceleration
- OVSP Over speed during operating
- PDER PID feedback loss
- STP0 Zero speed stop
- STP1 Fail to start directly
- STP2 Keypad emergency stop
- b.b. External base block